Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Rev. Cient. CRO-RJ (Online) ; 3(2): 32-36, May-Aug. 2018.
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1021859

RESUMO

Objective: to assess the accuracy of the nominal initial diameter of ProTaper Universal® finishing files and their respective gutta-percha cones. Method : ProTaper Universal® finishing files, F1, F2, F3, F4 and F5 and corresponding ProTaper cones were used (10 of each). A Profile Projector was used to evaluate the initial diameter of files and cones. All measurements were repeated twice and performed by a single trained operator. A descriptive analysis of the files' initial diameters was performed considering the tolerance limit established by the ADA number 101. According to this standard, the files F1, F2 and F3 have a tolerance limit of ± 0.025 mm and the files F4 and F5 ± 0.05 mm. The same tolerance limit was used to evaluate the cones. The initial diameters of the instruments and cones studied were compared with the nominal values given by the manufacturer through Student's T test (pd"0.05). Results: No finishing file group showed adequate accuracy (pd"0.05). Accuracy was verified only from the F5 ProTaper cone group (p> 0.05). It was verified that 30% (n=15) of the finishing files and 20% (n = 10) of the cones exceeded the tolerance limits. Conclusion : Accuracy was not observed for any file and it was identified only in the F5 ProTaper Universal® cone. Most files and cones were within the tolerance limits established by the ADA.


Objetivo: Analisar a acurácia do diâmetro inicial dos instrumentos de acabamento do sistema ProTaper Universal® e seus respectivos cones de guta-percha. Método: Foram utilizados instrumentos de acabamento do sistema ProTaper Universal® F1, F2, F3, F4 e F5 e cones de guta-percha ProTaper correspondentes (10 de cada). O projetor de perfil foi usado para avaliar o diâmetro inicial dos instrumentos e cones. Todas as medições foram feitas duas vezes por um único operador treinado. Uma análise descritiva do diâmetro inicial dos instrumentos foi realizada considerando o limite de tolerância proposto pela ADA número 101. De acordo com essa norma, os instrumentos F1, F2 e F3 tem um limite de tolerância de ± 0.025 mm e os instrumentos F4 e F5 ± 0.05 mm. O mesmo limite de tolerância foi utilizado para avaliar os cones. Os diâmetros iniciais dos instrumentos e cones estudados foram comparados com os valores nominais dados pelo fabricante através do teste T (pd"0.05). Resultados: Foi verificada acurácia somente do cone de guta-percha ProTaper do grupo F5 (p>0,05). Nenhum grupo de instrumento de acabamento apresentou acurácia (pd"0,05). Foi verificado que 30% (n=15) dos instrumentos de acabamento e 20% (n=10) dos cones excederam o limite de tolerância. Conclusão: Acurácia não foi verificada em nenhum instrumento ProTaper Universal® e somente o cone F5 apresentou acurácia. A maioria dos instrumentos e cones estavam dentro do limite de tolerância proposto pela ADA.


Assuntos
Endodontia , Tratamento do Canal Radicular , Precisão da Medição Dimensional , Guta-Percha
2.
Acta Odontol Scand ; 75(8): 584-587, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28799814

RESUMO

OBJECTIVE: Implantable cardioverter defibrillators (ICDs) are subject to electromagnetic interference (EMI). The aim of this study was to assess both the EMI of dental equipments with ICDs and related factors. MATERIALS AND METHODS: High- and low-speed handpieces, an electric toothbrush, an implant motor and two types of ultrasonic devices were tested next to an ICD with different sensitivity settings. The ICD was immersed in a saline solution with electrical resistance of 400-800 ohms to simulate the resistance of the human body. The dental equipments were tested in both horizontal (0°) and vertical (90°) positions in relation to the components of the ICD. The tests were performed with a container containing saline solution, which was placed on a dental chair in order to assess the cumulative effect of electromagnetic fields. RESULTS: The dental chair, high- and low-speed handpieces, electric toothbrush, implant motor and ultrasonic devices caused no EMI with the ICD, irrespective of the program set-up or positioning. No cumulative effect of electromagnetic fields was verified. CONCLUSIONS: The results of this study suggest that the devices tested are safe for use in patients with an ICD.


Assuntos
Desfibriladores Implantáveis , Equipamentos Odontológicos/efeitos adversos , Campos Eletromagnéticos/efeitos adversos , Impedância Elétrica/efeitos adversos , Humanos , Ultrassom
3.
Rev. odontol. UNESP (Online) ; 41(5): 360-364, set.-out. 2012. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-666266

RESUMO

Introdução: Uma fratura coronorradicular envolve esmalte, dentina e cemento, podendo ou não haver comprometimento pulpar. Vários tratamentos são propostos na literatura, desde a colagem do fragmento dental até a extrusão cirúrgica do fragmento remanescente. O presente trabalho descreve um caso de fratura coronorradicular com envolvimento pulpar e a abordagem multidisciplinar dada ao caso. Descrição do Caso Clínico: Paciente procurou tratamento odontológico por causa de um "dente quebrado". O tratamento realizado consistiu em um retalho mucoperiosteal para remoção dos fragmentos dentais, tratamento endodôntico, restauração provisória, extrusão ortodôntica, uma nova restauração e a proservação do caso. Conclusão: Em pacientes jovens, na região anterior, a extrusão ortodôntica acompanhada do tratamento restaurador é uma opção de tratamento conservador e estético.


Introduction: A crown-root fracture involves enamel, dentin and cementum. There may or may not be pulp involvement. Several treatments are proposed in the literature, going from a simple bond of dental fragments to surgical extrusion of the dental remaining fragments. The article describes a case of crown-root fracture with pulp involvement, and the multidisciplinary approach applied to the case. Case Report: Patient required dental treatment due to a "broken tooth". The treatment consisted in a mucoperiosteal flap to remove dental fragments, endodontic treatment, temporary restoration, orthodontic extrusion, a new restoration, and the follow-up of the case. Conclusion: While treating the anterior teeth of young patients, the orthodontic extrusion accompanied by restorative treatment is the most conservative and aesthetic option of treatment.


Assuntos
Humanos , Feminino , Criança , Ortodontia , Cemento Dentário , Esmalte Dentário , Dentina , Endodontia , Extrusão Ortodôntica
4.
Rev. odontol. UNESP (Online) ; 41(4): 242-246, jul.-ago. 2012. tab, ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-667024

RESUMO

Introdução: Nas últimas décadas, a Endodontia teve um grande avanço tecnológico e, dentre as mudanças nessa evolução, reduziu-se significativamente o tempo necessário para o preparo do canal radicular. Nesse contexto, soluções cada vez mais concentradas de hipoclorito de sódio (NaOCl) começaram a ser utilizadas. Objetivo: O  objetivo do presente trabalho foi avaliar os efeitos da temperatura e do tempo de armazenamento na estabilidade química de soluções de hipoclorito de sódio a 8% em diferentes pHs, comparando esses possíveis efeitos com aqueles relativos às concentrações comumente encontradas no mercado. Material e método: Soluções de NaOCl nas concentrações de 1%; 2,5%; 5,25% e 8% foram manipuladas com valores de pH 7 e 10,4. As amostras foram armazenadas à temperatura ambiente e em geladeira, tendo sido avaliadas após 1, 2 e 3 meses de armazenamento. Após os diferentes tempos experimentais, as amostras tiveram sua concentração determinada. A concentração de cloro ativo das soluções foi determinada por titulação, método da iodometria. Os dados foram avaliados estatisticamente. Resultado: Os resultados mostraram que o armazenamento da solução em geladeira, comparado àquele em temperatura ambiente, reduziu a perda de cloro ativo em todas as concentrações avaliadas e que, nestas diferentes concentrações, houve a perda do teor de cloro com o passar do tempo. Conclusão: As soluções de NaOCl a 8% mostraram-se mais instáveis à temperatura ambiente, quando comparadas àquelas armazenadas em geladeira, do que as demais concentrações avaliadas. A temperatura e o tempo de armazenamento afetaram a estabilidade química de todas as concentrações avaliadas.


Introduction: In recent decades, endodontics had great technological advances that have significantly reduced the time required for root canal preparation. In this context, increasingly concentrated sodium hypochlorite (NaOCl) solutions have been used. Objective: The aim of this study was to evaluate the effects of temperature and storage time on chemical stability of 8% sodium hypochlorite solutions, at different pHs, comparing with usual concentrations. Material and method: 1%, 2.5%, 5.25% and 8% NaOCl solutions, at pH 7 and 10.4 were manipulated. Paired samples were stored at room temperature and in a refrigerator and were evaluated after 1, 2 and 3 months of storage. After the different experimental times, the NaOCl concentration was determined. The active chlorine concentration of the NaOCl solutions was determined by iodometric titration. The data were statistically analyzed. Result: When the solution was stored in refrigerator, compared to room temperature, there was reduced loss of active chlorine in all tested concentrations. Over time there was loss of chlorine content in all solutions. Conclusion: 8% NaOCl solutions were more unstable than other concentrations tested at ambient temperature, as compared to those stored in the refrigerator. The temperature and storage time affected the chemical stability of all concentrations tested.


Assuntos
Hipoclorito de Sódio , Temperatura , Tempo , Cloro , Preparo de Canal Radicular , Estabilidade de Medicamentos , Concentração de Íons de Hidrogênio
5.
JBE j. bras. endodontia ; 5(21/22): 416-421, jul.-dez. 2005. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-521898

RESUMO

Reabsorção radicular é um processo patológico que pode resultar em perda do elemento dentário. Constitui, também, um problema clínico de diagnóstico e tratamento, em função de sua difícil identificação, o que dificulta, em consequência, seu prognóstico (Consolaro, 2002; Frank, 1981; Fus et al.,2003). Uma das formas de diagnóstico consiste no relato dos fatores etiológicos associados à patologia. Utilizando-se como critério a superficie dentária afetada, relacionam-se os casos de reabsorçoes internas a inflamação crônica (Frank, 1981; Fuss et al., 2003; Gunraj, 1999; Motta et al., 1997; Trope, 1998), trauma dentário Frank, 1981; Fuss, et al., 2003; Gunraj, 1999; Motta, et al., 1997) e pulpotomia Motta, et al., 1997) como os principais agentes desencadeantes. Enquanto que nos casos de reabsorções externas, agregam-se o trauma dentário (Bnenati, 2002; Frank, 1981; Fuss, et al., 2003; Gunraj, 1999; Motta et al., 1997; Trope, 1998), reimplante dentário (Benenat, 2002; Motta, et al., 1997) necrose pulpar...


Assuntos
Humanos , Feminino , Adulto , Cavidade Pulpar/lesões , Endodontia/métodos , Hipoclorito de Sódio/química , Óxido de Zinco/química , Reabsorção da Raiz/diagnóstico , Reabsorção da Raiz/patologia , Radiografia/métodos
6.
Rev. bras. odontol ; 53(5): 2-5, set.-out. 1996. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-187611

RESUMO

O objetivo do presente estudo foi comparar a capacidade de selamento apical das seguintes técnicas: condensaçäo lateral, híbrida de Tagger original e a modificada. Foram empregados 36 dentes unirradiculados humanos extraídos, que tiveram seus canais instrumentados e obturados pelas técnicas citadas. Os dentes foram imersos em corante e tiveram suas infiltraçöes apicais mensuradas. Nos espécimes obturados pela técnica da condensaçäo lateral, a infiltraçäo foi estatisticamente superior à das técnicas híbridas, enquanto näo foi observada diferenças entre a técnica híbrida original e a modificada


Assuntos
Humanos , Masculino , Feminino , Cavidade Pulpar , Infiltração Dentária , Guta-Percha , Técnicas In Vitro , Incisivo , Azul de Metileno , Obturação do Canal Radicular/métodos , Irrigantes do Canal Radicular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...